{"product_id":"cp-ols-rack-tower-1000va-900w","title":"CyberPower OLS Rack\/Tower 1000VA\/900W Online UPS – High-Performance Power Backup","description":"\u003ch1 style=\"text-align:center\"\u003e\u003cstrong\u003e\u003cspan style=\"color:#2980b9\"\u003eCyberPower OLS Rack\/Tower 1000VA\/900W Online UPS – High-Performance Power Backup | Buy Now at 7stores.au\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\n\n\u003ch2\u003e \u003c\/h2\u003e\n\n\u003ch2\u003e \u003c\/h2\u003e\n\n\u003ch2\u003e\u003cstrong\u003eCyberPower OLS 1000VA\/900W Online Rack\/Tower UPS – Professional-Grade Pure Sine Wave Power Protection for Business-Critical Equipment\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eCyberPower OLS 1000VA\/900W Rack\/Tower UPS\u003c\/strong\u003e is a \u003cstrong\u003ehigh-efficiency, online double-conversion uninterruptible power supply\u003c\/strong\u003e tailored for small-to-medium business networks, edge computing systems, telecommunications, and critical IT infrastructure. Featuring true online topology, this UPS provides \u003cstrong\u003econtinuous, clean, and isolated sine wave power\u003c\/strong\u003e, shielding sensitive equipment from power fluctuations, surges, sags, and harmonic distortion with \u003cstrong\u003ezero transfer time\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWith a \u003cstrong\u003ecompact 2U rack\/tower convertible design\u003c\/strong\u003e, this UPS is ideal for space-constrained server racks and standalone deployments. The system delivers \u003cstrong\u003e900W of reliable power with a 0.9 power factor\u003c\/strong\u003e, making it suitable for powering \u003cstrong\u003eservers, switches, security DVRs, NAS systems\u003c\/strong\u003e, and other essential devices. The included \u003cstrong\u003eSmart Battery Management (SBM)\u003c\/strong\u003e extends battery life, while \u003cstrong\u003eECO mode efficiency exceeding 95%\u003c\/strong\u003e helps reduce energy consumption and operational costs.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eOLS 1000VA UPS\u003c\/strong\u003e is equipped with \u003cstrong\u003e8 IEC C13 outlets\u003c\/strong\u003e, including \u003cstrong\u003e4 critical and 4 non-critical load segments\u003c\/strong\u003e, allowing prioritization of essential devices during outages. The integrated \u003cstrong\u003eLCD interface\u003c\/strong\u003e provides real-time status updates, alarm settings, and system control, while \u003cstrong\u003eSNMP\/HTTP remote monitoring\u003c\/strong\u003e support (via optional RMCARD205) enables centralized UPS management from anywhere.\u003c\/p\u003e\n\n\u003cp\u003eWith support for up to \u003cstrong\u003e3 extended battery modules (BPSE24V40ART2U)\u003c\/strong\u003e and \u003cstrong\u003eauto-detection functionality\u003c\/strong\u003e, runtime can be scaled easily for applications requiring prolonged backup. Surge suppression, \u003cstrong\u003eEMI\/RFI filtration\u003c\/strong\u003e, and \u003cstrong\u003eemergency power-off (EPO) support\u003c\/strong\u003e make this a robust and intelligent choice for reliable business continuity.\u003c\/p\u003e\n\n\u003cp\u003eNow available at \u003cstrong\u003e7stores.au\u003c\/strong\u003e, the CyberPower OLS 1000VA Rack\/Tower UPS combines \u003cstrong\u003eenterprise-level protection\u003c\/strong\u003e, \u003cstrong\u003esmart features\u003c\/strong\u003e, and \u003cstrong\u003eflexibility\u003c\/strong\u003e in a compact footprint—delivered by one of Australia's most trusted IT providers.\u003c\/p\u003e\n\n\n\u003ch3\u003e \u003c\/h3\u003e\n\n\u003ch2\u003e\u003cspan style=\"color:#2980b9\"\u003e\u003cstrong\u003eWhy Buy the CyberPower OLS 1000VA Rack\/Tower UPS from 7stores.au?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eTrue Online Double-Conversion Topology\u003c\/strong\u003e – Filters and isolates power for ultra-stable pure sine wave output\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003e0.9 Power Factor with 900W Output\u003c\/strong\u003e – Supports servers, storage, network gear, and sensitive electronics\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRack\/Tower Convertible 2U Design\u003c\/strong\u003e – Easy integration into rack cabinets or desktop\/server room environments\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eZero Transfer Time\u003c\/strong\u003e – Maintains uninterrupted power for mission-critical systems\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSmart Battery Management (SBM)\u003c\/strong\u003e – Enhances performance, diagnostics, and battery lifespan\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eExtended Battery Module (EBM) Support\u003c\/strong\u003e – Scale runtime with up to 3 additional battery packs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSurge and Spike Protection (363 Joules)\u003c\/strong\u003e – Guards against electrical transients and surges\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eEMI\/RFI Filtration \u0026amp; Network Protection\u003c\/strong\u003e – Protects connected devices and communication lines\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRemote Management Ready\u003c\/strong\u003e – SNMP\/HTTP via optional RMCARD205\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eAvailable Now at 7stores.au\u003c\/strong\u003e – Fast delivery, expert advice, and Australian warranty coverage\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e \u003c\/h3\u003e\n\n\u003ch2\u003e\u003cspan style=\"color:#2980b9\"\u003e\u003cstrong\u003eProduct Specifications – CyberPower OLS Rack\/Tower 1000VA\/900W UPS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003ch4\u003e \u003c\/h4\u003e\n\n\u003ch4\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CyberPower OLS1000E Rack\/Tower\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eTopology:\u003c\/strong\u003e Online Double Conversion\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 2U Rackmount \/ Tower Convertible\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOutput Capacity:\u003c\/strong\u003e 1000VA \/ 900W\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e 0.9\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eGenerator Compatible:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eEfficiency (ECO Mode):\u003c\/strong\u003e \u0026gt;95%\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 230V ±10%\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 160 – 300V\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eAdjustable Range (Based on Load):\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e80–300V @ 30% Load\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e120–300V @ 60%\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e140–300V @ 80%\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e160–300V @ 100%\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 50 ±10Hz \/ 60 ±10Hz\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eFrequency Detection:\u003c\/strong\u003e Auto-sensing\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 4.5A\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eInput Power Factor:\u003c\/strong\u003e 0.99\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eInput Connector:\u003c\/strong\u003e IEC C14\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003ePower Cord Length:\u003c\/strong\u003e 1.5m\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eWaveform Output:\u003c\/strong\u003e Pure Sine Wave\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eVoltage Settings:\u003c\/strong\u003e 208 \/ 220 \/ 230 \/ 240V ±1%\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eFrequency Settings:\u003c\/strong\u003e 50 ±0.5Hz \/ 60 ±0.5Hz (Configurable)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOutlet Count:\u003c\/strong\u003e 8 × IEC C13\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eLoad Segmentation:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e4 Critical Load (CL)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e4 Non-Critical Load (NCL)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eTransfer Time:\u003c\/strong\u003e 0 ms\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eCrest Factor:\u003c\/strong\u003e 3:1\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eHarmonic Distortion:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eLinear Load: ≤3%\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eNon-Linear Load: ≤5%\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOverload Protection – Line Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e110–120% for 1 min\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\n\t\t\u003cp\u003e120% – Immediate shutdown\u003c\/p\u003e\n\t\t\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOverload Protection – Battery Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e110–120% for 10 sec\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\n\t\t\u003cp\u003e120% – Immediate shutdown\u003c\/p\u003e\n\t\t\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOverload Protection – Bypass Mode:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\n\t\t\u003cp\u003e130% – Immediate shutdown\u003c\/p\u003e\n\t\t\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eInternal Bypass:\u003c\/strong\u003e Manual \u0026amp; Automatic\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Sealed Lead-Acid\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eBattery Cartridge:\u003c\/strong\u003e RBP0156\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e1 cartridge with 2 × 12V\/9Ah\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e24V total\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eUser Replaceable:\u003c\/strong\u003e Yes – Qualified Personnel\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSmart Battery Management:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eStart On Battery:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRuntime at Half Load:\u003c\/strong\u003e 11 minutes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRuntime at Full Load:\u003c\/strong\u003e 4 minutes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRecharge Time:\u003c\/strong\u003e 4 hours\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eMax Charging Current:\u003c\/strong\u003e 1.5A\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eCompatible EBM:\u003c\/strong\u003e BPSE24V40ART2U\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eEBM Auto-Detection:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eMax EBM Quantity:\u003c\/strong\u003e 3\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eMonitoring \u0026amp; Management\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e Color LCD with real-time information and control\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eLCD Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eMode Setting\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eInput\/Output Monitoring\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eBattery Config\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eFault\/Alarm Settings\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eLogs and Event Data\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eUSB Port:\u003c\/strong\u003e 1 × HID Compliant\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eDry Contact Relay:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSNMP\/HTTP Monitoring:\u003c\/strong\u003e Optional RMCARD205\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eEmergency Power Off (EPO):\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eAudible Alarms:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eLow Battery\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eBattery Mode\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eOverload\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eUPS Fault\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eReplace Battery\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eOverheat\/Overcharge\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSurge Suppression:\u003c\/strong\u003e 363 Joules\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eEMI\/RFI Filtering:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eNetwork Line Protection:\u003c\/strong\u003e RJ11\/RJ45 Combo – 1-in, 1-out\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eChassis:\u003c\/strong\u003e Metal\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eDimensions (WxHxD):\u003c\/strong\u003e 438 × 88 × 430 mm\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 13.5 kg\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRackmount Kit:\u003c\/strong\u003e Rail \u0026amp; Ears Included\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2-Year Advanced Replacement\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CyberPower","offers":[{"title":"Default Title","offer_id":47823292629157,"sku":"OLS1000ERT2Ua","price":759.09,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/9556\/4965\/files\/OLS1000ERT2Ua_c13123fe-9f91-4552-bd16-b66c9d7657ae.jpg?v=1778613515","url":"https:\/\/www.7stores.au\/products\/cp-ols-rack-tower-1000va-900w","provider":"7Stores.net","version":"1.0","type":"link"}